Sectors Industrial safetyIndustrial automationRailway & tramwayDoors & gates Products Why Tecnel System Resources News Contact Italiano
Product area: Railway & tramway transport

Special cables

Wide range of single-core, multi-core, miniaturised, UIC, JUMPER system and custom-specification cables.

Manufactured in accordance with current regulations and the safety standards required by public transport. They are also networked with ion-beam irradiation for optimal fire and mechanical resistance, with reduced dimensions and weight.
The cables BETAtherm® ENgine, BETAflam® ENgine and BETAtrans® GKW provide longer service life even at elevated temperatures and therefore higher current-carrying capacities.

Reference standards: BS 6853 – BS 6387 – DIN 5510-2 – NFF 16-101 – EN 50306 – EN50264 – EN 50265 – EN 50266 – EN 50267 – EN 50268 – EN 50305 – EN 50200 – EN 60332 – EN 60684 – EN45545-2 – IEC 60331 – NFPA 130

  • Risk Level HL1 and HL3 (EN 45545-2)
  • Flame resistant (EN 50266-2-4; EN 50266-2-5; EN 50305)
  • Non-propagation of fire (EN 60332-1-2)
  • Low smoke density (EN 61034-2)
  • Halogen-free (EN 50267-2-1; EN 60684-2)
  • Low toxicity (NF X70-100; EN 50305)
  • High resistance to fluids
  • Resistance to extremely low temperatures (Minimum operating temperature: -55 °C)
  • Power and signal cables with reduced insulation (EN 50264-3-1 and EN 50264-3-2): Single-core and multi-core, shielded and unshielded, with operating voltage from 300/500 V up to 3.6/6 kV. Operating temperature: -40 °C to +120 °C
  • Thin-wall cables (EN 50306): Single-core and multi-core, shielded and unshielded, with operating voltage 300/500 V. Operating temperature: -40 °C to +120 °C
  • High-temperature cables (IEC 60331-11): Single-core cables with operating voltages 300/500 V, 0.6/1 kV, 1.8/3 kV. Operating temperature: -40 °C to +120 °C for 180 min.
  • Data transmission cables: Data transmission cables for MVB, WTB, CAT5, CAT6, CAT7. Cables according to UIC 558 standards with 2, 4, 16, 18 conductors and UIC 541-5 with 9, 10, 12 conductors.
  • Cables with jumper systems: Complete jumpers for box-to-box connections

Cables have been designed to operate at high temperatures while reducing premature ageing in accordance with IEC 60216 – VDE 0304 Part 21 (see Arrhenius curve).

According to IEC 60216 and VDE 0304 Part 21 (life – operating temperature). Data referring to 20 000 h are derived for a temperature of +120 °C. An increase of +10 °C in operation allows the cable life to be doubled.